clear all close all clc %%%%%%%%%%%%%%%%%%%%%%% %% Set the model parameters % Large side windows window_size = [2.5 25]; window_roof_size = [5 5]; surface_part = 0.1; U = 1.8; % heat transfer coefficient [W/m2K] g = 0.7; % total solar energy transmittance v_g = 0.65; % transmittance in visible range of the sunlight % Roof wall_size = [25 25]; roof_position = [0 0 0]; % The roof is supposed to be made of [5cm wood, 10cm insulation, 5cm wood] node_thickness = [0.05 0.10 0.05]; % Data from 03.03 email with Manuel % Data from https://simulationresearch.lbl.gov/modelica/releases/latest/help % /Buildings_HeatTransfer_Data_Solids.html#Buildings.HeatTransfer.Data.Solids.Plywood node_conductivity = [0.12 0.03 0.12]; node_capacity = [1210 1200 1210]; node_density = [540 40 540]; % Floor ceiling_size = [25 25]; % The floor is supposed to be made of [] layer_thickness = [0.05 0.10 0.20]; layer_conductivity = [0.12 0.03 1.4]; layer_capacity = [1210 1200 840]; layer_density = [540 40 2240]; %% Set the run parameters air_exchange_rate = 2.0; power = 0; Te = 60*60*24*365; sim("polydome_model_1")