42 lines
1.2 KiB
Text
42 lines
1.2 KiB
Text
Model Parameters
|
|
================
|
|
|
|
Side Windows
|
|
------------
|
|
windows_size - [height width] of the large side-windows
|
|
window_roof_size - [height width] of the roof windows (approximated as one large window as opposed to
|
|
the four smaller windows in
|
|
reality)
|
|
surface_part - ???
|
|
U - heat transfer coefficient [W/m2K] (of the window?)
|
|
g - total solar energy transmittance
|
|
v_g = 0.65 - transmittance in visible range of the sunlight
|
|
|
|
|
|
Roof
|
|
----
|
|
wall_size - [length width] of the roof (considered flat)
|
|
roof_position - position angles of the roof
|
|
|
|
|
|
Roof structure
|
|
~~~~~~~~~~~~~~
|
|
The roof is supposed to be made of
|
|
- 5cm wood
|
|
- 10cm insulation
|
|
- 5cm wood
|
|
|
|
Data from https://simulationresearch.lbl.gov/modelica/releases/latest/help/Buildings_HeatTransfer_Data_Solids.html#Buildings.HeatTransfer.Data.Solids.Plywood
|
|
|
|
node_thickness
|
|
node_conductivity
|
|
node_capacity
|
|
node_density
|
|
|
|
Floor
|
|
-----
|
|
ceiling_size
|
|
layer_thickness
|
|
layer_conductivity
|
|
layer_capacity
|
|
layer_density% Large side windows
|